Contactor Snubber Switch 40 AMP

£167.99 Inc. VAT
£139.99 Ex. VAT

In Stock for Next Working Day Delivery

Loading...
Part No: HE-SN40 / EAN: 8711426851061
REGULAR INSTALLER OR BUSINESS?

Sign Up For A Trade Account HERE
  • For Switching Loads Over 16 amps – Over 5.8kW
  • Compatible With All Living Heat & Modern Thermostats
  • Compatible With All Floor Finishes
  • DIN Rail or Surface Mountable
  • Supports Integration With RCD or MCB For Safety
  • Free Technical Support
  • Next-Day Delivery Available Across The UK

Contactor Snubber Switch

40 AMP AC/DC

High-Performance 40A Contactor with AC/DC Coil

The Contactor Snubber Switch 40 AMP AC/DC is essential for electric underfloor heating systems drawing currents above 16 amps.

It allows a single thermostat to safely control high-load heating circuits by switching the main load through the contactor, protecting the thermostat from overload.

Key Applications & Uses

  • Switching high-load electric underfloor heating circuits over 16 amps
  • Integration with standard thermostats for safe load management
  • Domestic, commercial, and industrial underfloor heating systems
  • Compatible with both AC and DC control circuits
  • Reliable solution for multi-zone heating installations
  • Prevents wear and damage to thermostats from high-current loads

Technical Specifications

  • Rated Current: 40 A
  • Coil Voltage: AC/DC (compatible with standard thermostat outputs)
  • Switch Type: Snubber-protected contactor
  • Maximum Switching Power: 9,280 W (depending on load and installation)
  • Operating Temperature Range: -20 °C to 50 °C
  • Mounting: DIN Rail or Surface Mountable
  • Dimensions: Approx. 90 mm (H) × 35 mm (W) × 60 mm (D)
  • Electrical Protection: Supports integration with RCD or MCB for safety
  • Durability: Designed for long-term use in underfloor heating systems
  • Warranty: 1 Year Manufacturer’s Warranty

Why Choose This Contactor

This 40 A snubber contactor ensures safe operation of high-load heating circuits while allowing a standard thermostat to control the system efficiently.

Ideal for:

  • Large open-plan areas with multiple heating circuits
  • Commercial spaces where multiple zones require reliable switching
  • Retrofit projects where high-current underfloor heating systems are added to existing thermostats

Installation Guidance

Always connect the contactor to a dedicated power supply and integrate it with suitable RCD/MCB protection.

Ensure wiring complies with local electrical regulations.

Installation should be carried out by a qualified electrician to guarantee safety and compliance.

Support & Technical Advice

Living Heat provides full technical support for the installation and selection of contactors in underfloor heating systems.

For guidance, system design advice, or product questions, contact us at:

📧 sales@livingheat.co.uk
📞 01803 316060

Technical Information

Contactor Snubber Switch – 40 A AC/DC

High-Performance 40 A Contactor with AC/DC Coil

The Contactor Snubber Switch 40 A AC/DC is essential for electric underfloor heating systems that draw currents above 16 amps.

It allows a single thermostat to safely control high-load heating circuits, switching the main load through the contactor and protecting your thermostat from overload.


Key Applications & Uses

  • Switching high-load electric underfloor heating circuits over 16 amps

  • Integration with standard thermostats for safe load management

  • Domestic, commercial, and industrial underfloor heating systems

  • Compatible with both AC and DC control circuits

  • Reliable solution for multi-zone heating installations

  • Prevents wear and damage to thermostats from high-current loads


Technical Specifications

  • Rated Current: 40 A

  • Coil Voltage: AC/DC (compatible with standard thermostat outputs)

  • Switch Type: Snubber-protected contactor

  • Maximum Switching Power: 9,280 W (depending on load and installation)

  • Operating Temperature Range: -20 °C to 50 °C

  • Mounting: DIN Rail or Surface Mountable

  • Dimensions: Approx. 90 mm (H) × 35 mm (W) × 60 mm (D)

  • Electrical Protection: Supports integration with RCD or MCB for safety

  • Durability: Designed for long-term use in underfloor heating systems

  • Warranty: 1 Year Manufacturer’s Warranty


Why Choose This Contactor

The 40 A snubber contactor ensures safe operation of high-load heating circuits while allowing a standard thermostat to control the system efficiently. Ideal for:

  • Large open-plan areas with multiple heating circuits

  • Commercial spaces where multiple zones require reliable switching

  • Retrofit projects where high-current underfloor heating is added to existing thermostats


Installation Guidance

  • Connect the contactor to a dedicated power supply.

  • Integrate with RCD/MCB protection for safety.

  • Ensure all wiring complies with local electrical regulations.

  • Installation should be carried out by a qualified electrician to guarantee safety and compliance.


Support & Technical Advice

Living Heat provides full technical support for the installation and selection of contactors in underfloor heating systems.

Customers also purchased...

Get in touch!

At Living Heat Ltd, we offer a personal experience. That is tailored to get you the right product at the right price.

For more information on any of our products please get in touch, we are here to help.

Call Us

+44 (0)1803 316060

Email Us

sales@livingheat.co.uk

Get A Quote

Can I get a completely free, no pressure Underfloor Heating Quote? ... At Living Heat Ltd we know working out what you need can be a daunting task so let us take the pressure off.

Quick Deliveries
Competitively Priced
Lifetime Warranty
Click & Collect