Electric Underfloor Heating Experts
To install underfloor heating under tiles, lay insulation boards on a clean, sound subfloor, test the heating, then roll out the mat or lay the loose wire, leaving a 100mm unheated border. Fit the floor sensor, test again, and tile over it. A qualified electrician makes the final connection through an RCD.

In larger rooms, our 150W or 200W heating mats are the best solution. The mats are rolled out, cut and turned to fit the area. For the heating to work as a primary or secondary heat source, we recommend heating 80–90% of the available floor.
The mats are 500mm wide, so how much of the floor you can cover depends on how many 500mm runs fit in the room. Never order a mat for 100% of the floor, because it won’t fit. Allow at least a 100mm unheated border around the room when working out what you need.

In awkward or smaller rooms, like cloakrooms and WCs, loose wire is the choice of most installers. It isn’t fixed to a mesh, so it’s very versatile and can be laid wall to wall. As with mats, lay it directly onto insulation boards for the best efficiency and response.
If you’re not sure which suits your room, give our technical team a call.
The heating mat or loose wire, a thermostat with its floor sensor, insulation boards, flexible tile adhesive, and a multimeter to test the heating at each stage. Lay the heating directly onto XPS or cement-coated tile backer insulation boards.


Test the cable for continuity and resistance before you unroll it, and note the reading on the warranty page. Then work out the spacing between cable runs:
Spacing (mm) = 1000 ÷ cable length (m) × heated area (m²)
The answer should come out between 50mm and 80mm. It’s a guide to the spacing you need for the best coverage. Never cut or shorten the heating cable. To heat a bigger area, increase the spacing. To heat a smaller area, reduce it. Only the black cold connection ends can be shortened or lengthened.

You can test the heating as often as you like, but to complete the warranty it must be tested three times: before it’s laid, after it’s laid, and after the floor covering is down. Record every reading accurately on the warranty page.
We recommend 80–90% of the available floor. Never order a mat for 100% of the floor, and allow at least a 100mm unheated border around the room.
XPS or tile backer boards both work. We recommend 10mm, or 6mm if floor height is an issue. Over concrete, we highly recommend insulating.
You can cut the mesh backing to turn the mat, but never cut the heating cable.
No. Change the spacing between runs instead. Only the black cold connection ends can be shortened or lengthened.
Between two heating wires, no more than 30mm from one of them, and away from anything that could affect it, like hot water pipes.
Yes. All electrical connections must be made by a qualified electrician, and the system must run through an RCD.
Want to know what it all costs? See our electric underfloor heating cost guide, or call us on +44 (0)1803 316060 and we’ll help you choose.
At Living Heat Ltd, we offer a personal experience. That is tailored to get you the right product at the right price.
For more information on any of our products please get in touch, we are here to help.
Can I get a completely free, no pressure Underfloor Heating Quote? ... At Living Heat Ltd we know working out what you need can be a daunting task so let us take the pressure off.