Tile Backer Insulation Boards

6

6mm Thick

Will bounce your heat upwards sufficiently if height is an issue

6

10mm Thick

Recommended as standard. Will give that little extra insulation

6

20mm Thick

A little far for simply insulating. However, perfect for building up floor heights

6

30mm Thick

30 ton compression ratio designed for use under tile and stone

Cementatious Tile Backer Boards. (Wall and Floor Boards)

Cementatious tile backer boards are designed to insulate and water proof walls and floors. Ideal for wet room installations, the boards can be used directly under tile, stone, wood and laminate floors. It can also be used under mosaic, vinyl and carpet flooring but must first have a 9+mm layer of flexible self leveling installed over prior to the vinyl or carpet being fitted. The insulation comes in 6, 10, 20mm & 30mm depths. The steps below are listed to help guide you through the installation process.

1A: If you are fitting tile backer board to a floor loosely or with tile adhesive
please follow the instructions on page 9 – 10 (Hard insulation boards)

1B: If you are screwing the boards in place or tanking a room please follow
the instructions below.

2: The sub-floor or walls whether concrete, wood or plasterboard should be made suitable for the chosen floor covering, (ie tiles) prior to any boards being fitted. The boards are designed to provide increased insulation levels not structural rigidity.

3: Tile backer boards can be screwed to walls and floors using suitable fixing discs and screws. The discs must be located at 300mm centres or closer, (minimum 15 fixings per 1200 x 600 board). If the boards are to be screwed directly to stud walling the supporting stud work must be fitted at 300mm centers, (6mm boards are for floor only and not suitable for walls due to their insufficient structural rigidity).

4: Fit the boards to the wall / floor making sure to butt the boards tightly together to achieve a full floor / wall coverage. It is good practice to stagger joints between
boards and if necessary a flexible floor adhesive can be used to fill any small gaps between boards. It is important the boards are fixed securely to walls and consideration given to the weight of subsequent wall coverings. On floors the boards are not designed to bridge gaps and must be screwed back tight to the
floor surface to avoid any bounce as this could adversely affect subsequent layers.

5: If boards need to be cut to size this is easily done with a sharp Stanley knife.

6: If the boards are to be used to tank a room then we recommend the use of our aqua seal tape to be applied to all joints (as per the aqua seal jointing tape instructions).

6: Once the boards are fitted care should be taken not to apply excessive point loads to the insulation until the subsequent surfaces have been installed. Small dents and damage caused to the surface of the boards are quite normal and of no concern. If however the boards are to be left exposed for long periods of time or other work is to be carried out over the boards they should be covered with sheets of ply or other hard sheet material to minimize the chance of damage.

7: It is advisable to fit the final floor covering as soon as possible once the insulation has been installed. When fitting the chosen final floor covering it is advisable to work on top of a hard board. This will help prevent damage to the insulation when the work is being carried out.

8A: Wood and laminate flooring. Both underfloor heating and wood type tongue and grove flooring can now be fitted directly over the insulation in accordance with the manufactures fitting instructions. Care should be taken to avoid leaving any high spots caused by the screws/fixing discs. If these screws/discs are a problem they can be screwed down further to pull them flush with the board surface. Make sure not to over tighten these screws/discs.

8B: Tile & Stone Flooring All tiles can now be fitted directly over the insulation. A suitable flexible tile adhesive should be used as directed by the adhesive manufacture. The tiling should be carried out in the normal way making sure to fit the tiles with a full bed of adhesive, (never dot and dab tiles). If Mosaic tiles are to be fitted a scrim tape should be fitted over all board joints to provide extra support.

8C: Vinyl & carpet. When fitting non rigid sheet material over the insulation boards, first a 8mm layer of flexible leveling compound should be fitted over the insulation. This will provide protection from high point loads as it will spread the weight over the insulation surface allowing the subsequent layers to be fitted. The leveling should be fitted in accordance with the manufactures instructions. (In high traffic or commercial areas, all board joints should have a scrim tape applied prior to the leveling being fitted).

8D: Wall tiles should be fitted in the normal way making sure to use a full bed of adhesive. The adhesive should be a flexible wall adhesive and applied / mixed in accordance with the manufactures instructions.

KEEP AN EYE OUT !

From time to time we add new fantastic products and offer some fantastic deals

Free Delivery

Free Next Day Delivery

No Better Price

Price Match Promise

Lifetime Warranty

On Selected Products

30 Day Returns

No Quibble Returns

Social

Please feel free to share our great products with friends and family and let them experience the benifits of underfloor heating.